A barb is a spigot with one or more ridges that you push a soft tube onto. The tube stretches to clear the ridge and, right behind it, tries to return to its own diameter: that squeeze is both the seal and almost all of the grip. It is the cheapest fluid connection there is and one of the simplest to print, provided you size it from a measurement of the tube you will actually use and print it so that neither the seam nor the layers open a leak.

Anatomy of a barb and how it grips

From tip to root, a barb has these parts. First the lead-in tip, slightly narrower than the tube's inside diameter (ID) so the tube starts by hand. Then the ramp, a gentle cone. Then the crest, the widest point. Behind it, the back face, a step square to the axis. Between ridges, the land, a plain section at the tube's ID. Inside, the bore. And at the root, the collar (or a hex), which acts as a stop.

Clamp behind the last ridgeClamp over the crestCollarSeal lineCrestCrest = k · ID (k = 1.10–1.30)RampLand between ridgesLand ≥ 2 · tTubePlain shankBoreα = 10–20°Lead-in tipStepped back facePlain shank = tube IDRidges too close: the tube bridges and only the last one worksPressure inflates the tube and lifts it offPulling narrows the tube and grips harder
Half section of a two-ridge barb with the tube fitted. The tube seals just behind each crest, where it recovers its diameter; the clamp sits on the plain shank, never over a ridge.

The back face has to be a sharp-edged step. The seal line is the edge of the crest, exactly where the stretched tube recovers its diameter. If the crest is rounded, the tube slides back; a sharp edge holds it. On a printed barb, that edge depends on the layers, and so on how you print it.

Pull on the tube and it narrows and hugs the barb harder; raise the internal pressure and it inflates and lifts off the crest. That is why a barb warns you by dripping before it lets go.

As for the number of ridges, one good ridge does all the sealing, which is why some manufacturers sell single-ridge barbs. Extra ridges only add grip if the tube can close down again between them. If they are too close, the tube bridges from crest to crest and only the last one works. What a second ridge does add is a backup seal line in case the first has a defect. As a starting point, use two or three ridges, separated by a plain land of at least twice the tube wall (from the back face of one to the ramp of the next). Soft silicone seals well on one ridge. Stiffer tubes (PVC, PU, PE) want two or three.

Clear silicone tube on a printed two-ridge barb: the tube bulges over each crest, closes down again behind it, and the clamp sits on the plain shank
Clear silicone tube on a printed two-ridge barb: the tube bulges over each crest, closes down again behind it, and the clamp sits on the plain shank

The clamp goes behind the last ridge, on the plain shank. There it keeps the tube narrower than the crest, and pressure pushes the tube against the back face instead of lifting it. Over the crest it does the opposite: it lifts the tube off the edge and opens the leak. On very soft tube, do not tighten it fully and avoid plastic cable ties: they pucker the tube and lift it. Fit a clamp when you do not know the pressure or temperature, with vibration, with stiff tube, or with a tube that has been fitted and removed so often it no longer recovers its shape. To make room for it, leave a plain shank as wide as its band plus about 2 mm; measure the band of the clamp you will actually use.

Sizes: from the tube to the barb

A barb is sized from the tube's ID. These are the most common tube families. They are market conventions, not standards.

Common tubing (ID × OD, mm), typical values
Use ID × OD Source
Aquarium airline (Europe) 4 × 6 aquarium retailer listings
Aquarium airline (US), 3/16″ × 1/4″ 4.76 × 6.35 bulkreefsupply.com
"1/4″" drip micro-tubing (US), 0.170″ × 0.250″ 4.3 × 6.35, no industry standard dripworks.com
PC liquid-cooling soft tubing, on G 1/4 fittings 10 × 13, 10 × 16, 13 × 19 (12.7 × 19) fitting manufacturers' datasheets
Garden hose 13 (1/2″), 15 (5/8″) and 19 (3/4″) ID, estimate see Garden hose threads
Lab or pump silicone tubing ID and wall vary by manufacturer measure it

"4 mm" airline and 3/16″ airline are not the same tube: 4.0 against 4.76 ID. A barb designed for 3/16″ has its crest at about 5.7 mm; on a 4 mm tube that is 43 % stretch. The tube is hard to push on and silicone splits. The other way round, a barb for 4 mm tube drips in 3/16″ tube. Measure the ID with the shank of a drill bit or with gauge pins; do not trust the label. The method is in Measuring an undocumented standard.

Commercial barbs show which proportions work:

Real plastic barbs (Eldon James, inches converted to mm, approximate)
Tube ID Tip (= ID) Crest Bore Crest / ID
1/8″ (3.18) 3.18 4.09 1.91 1.29
1/4″ (6.35) 6.35 7.62 3.56 1.20
3/8″ (9.53) 9.53 11.43 6.35 1.20
1/2″ (12.7) 12.7 14.48 9.35 1.14
3/4″ (19.05) 19.05 21.72 14.73 1.14
1″ (25.4) 25.4 27.94 20.32 1.10

Source: eldonjames.com, Barb_Thread-Information.pdf, accessed 2026-11-17; the manufacturer gives them as approximate. One manufacturer's data, not a standard.

On those single-ridge barbs, the tip is exactly the tube's ID. The crest sits 10 to 30 % above it: 29 % at 1/8″, 20 % at 1/4″ and 3/8″, and 10–14 % from 1/2″ to 1″. The bore runs at about 0.55–0.8 times the ID. As a reference from another manufacturer, Nordson's 400 series (its easy-assembly line for semi-rigid tubing) stretches the tube 25 % over its nominal ID.

From that come some starting proportions for a printed barb. They are estimates made for this article, not catalog data; in particular, a plain shank equal to the ID and a land of two walls are judgment, not a standard:

Starting proportions for a printed barb (estimate)
Dimension Value
Plain shank and land measured tube ID
Lead-in tip ID − 0.5 mm, to start by hand
Crest, silicone and soft PVC 1.15 × ID
Crest, stiff PVC, PU, PE 1.10 × ID
Crest, tubes under 5 mm ID 1.20–1.25 × ID
Ramp half-angle 10–20° to the axis
Back face step at 90° to the axis
Land between ridges ≥ 2 × tube wall
Number of ridges 2–3 (1 is enough in silicone)
Barb wall ≥ 1.2 mm (3 perimeters)
Clamp section band width + 2 mm

A steeper ramp grips harder but makes the tube harder to push on. Make the bore as wide as the minimum wall allows.

On a printed barb the outside diameters are what matter, and they come out on size or slightly oversize, the opposite of a hole (the asymmetry is in Why holes print small). Model it at nominal, print one, measure the crest and the plain shank with callipers and correct the matching named parameter.

How much pressure it takes

There is no catalog figure for "a barb". The pressure is held by the tube, barb and clamp together, and the manufacturers themselves ask you to test with your tube. What you can estimate is the order of magnitude.

The stretched tube squeezes the barb with a contact pressure you can work out as if it were a thin ring of linear elastic material. The result can be out by up to a factor of two:

Estimates for a barb
Quantity Formula Meaning
Contact pressure p_c ≈ E · ε · t / r_m E: tube modulus; ε: stretch (crest/ID − 1); t: wall; r_m: mean radius over the crest
Modulus of Shore 60A silicone E ≈ 3.6 MPa Gent's hardness–modulus relation, estimate
Axial force from pressure F = p · π · ID² / 4 axial push of the pressure on the tube

The joint starts to weep when the internal pressure approaches p_c. The axial force, on the other hand, is small: 0.5 bar on an 8 mm ID pushes with 2.5 N, so the barb drips long before the pressure pushes the tube off. What pulls a tube off or breaks the barb is a tug, a bend or a sideways lever.

As a guide, not as catalog data:

  • A barb with silicone tube, no clamp and 15 % stretch is fine for drip irrigation, aquarium air, pumps of a few hundred mbar and low-pressure cooling loops.
  • From roughly 1 bar, or with warm water, vibration or stiff tube, fit a clamp.
  • At household mains pressure (3–4 bar), use a threaded fitting with a washer, a clamp and reinforced hose.

Above all, the tube's rated pressure at the working temperature has the last word: look it up on its datasheet.

Temperature affects both the tube and the barb. PVC softens with heat, and in the cold it stiffens and keeps its deformation: warm it to fit it, and if it is cold and deformed, clamp it. The printed barb has its own limit under sustained load: about 40 °C for PLA, about 50 °C for PETG and about 80 °C for ASA (Heat, cold, sunlight and chemicals). PLA is no good for hot water.

Worked example: a tee for 8 × 12 silicone tube

A small 12 V pump waters three plant pots through 8 × 12 mm Shore 60A silicone tube, at 0.5 bar at most and with cold water. The line runs past all three, and at each one a printed PETG tee feeds a branch.

  1. Measure. The tube slides snugly over the shank of an 8.0 mm drill bit. The wall measures 2.0 mm.

  2. Barb. Plain shank 8.0. Crest 1.15 × 8.0 = 9.2 (15 % stretch). Lead-in tip Ø7.4, so the tube starts by hand. Ramp at 15°: its length is (9.2 − 7.4) / 2 / tan 15° = 0.9 / 0.268 ≈ 3.4 mm. Stepped back face of 0.6 mm. Two ridges with 4 mm of land between them (2 × wall); the second ridge's ramp, from Ø8.0 to Ø9.2, is 0.6 / tan 15° ≈ 2.2 mm long. First pass: 6 mm of plain shank behind, and the barb is about 16 mm long (3.4 + 4 + 2.2 + 6).

  3. Bore and wall. Bore Ø5.0, which leaves (8.0 − 5.0) / 2 = 1.5 mm of wall: 3–4 perimeters. Bore/ID = 0.63, inside the range of commercial barbs.

  4. Does it seal? p_c ≈ 3.6 × 0.15 × 2.0 / 5.6 ≈ 0.19 MPa ≈ 1.9 bar. That is an upper bound: at the mean radius the stretch is a little lower and the wall thins as it stretches, so count on 1.5–1.9 bar, three to four times the 0.5 bar working pressure. No clamp needed.

  5. Will the barb snap? A 20 N sideways tug at the tip, 16 mm out, gives M = 320 N·mm at the root. Annular section Ø8/Ø5: Z = π(D⁴ − d⁴) / (32 · D) = π(4096 − 625) / 256 ≈ 42.6 mm³, and σ ≈ 7.5 MPa. For design, assume the part is half as strong in Z as in XY (Layer adhesion and anisotropy): in PETG, 0.5 × 51 = 25.5 MPa. With a safety factor of 4 that leaves 6.4 MPa. It fails. The fix has three parts:

    • Ø4 bore along the whole barb: Z = π(4096 − 256) / 256 ≈ 47 mm³.
    • A shorter barb: drop the clamp section, which step 4 does not call for, and leave 2 mm of plain shank after the last ridge. The barb is now about 12 mm long, M = 240 N·mm and σ = 240 / 47 ≈ 5.1 MPa: under the limit.
    • A 1.5 mm fillet at the root against the collar, which removes the stress concentration.

    The price is flow: the bore passes (4/8)² = 0.25 of the tube's cross-section, below the commercial range. For drip irrigation that is plenty; for a cooling loop, it is not. If you ever need a clamp, the 10–12 mm of plain shank it needs lengthens the barb and the root no longer passes: use a brass barb then. And in any case, fix the tube to the pot or the bench so nobody levers on the tee (Clips for tubes and cables). The safety factor is explained in Estimating whether a part will hold.

  6. Orientation. The three barbs of a flat tee cannot all be vertical. Redesign the tee as a Y: the inlet vertical, tip down on the bed, and the two outlets pointing up at ±30° from vertical. The inlet barb stands on a Ø7.4 ring, so add a brim. Its ramp, upside down, is a 15° overhang, and the outlets at 30° sit well within the 45° that prints without supports.

  7. Test. Water at 1.5 × 0.5 = 0.75 bar for 10–15 min, a pull by hand and 48 h in service.

Printing it so it does not drip

Print the barb with its axis vertical. Each ridge comes out as a stack of circles, and the layer steps run round the barb, parallel to the seal line: like the ridges themselves, they open no path for water along the axis. Tip up, the ramp narrows as it rises and has no overhang, and the back face is a small downward-facing ledge: at 0.6 mm (8 mm tube and 15 % stretch) it prints clean. On large tubes the ledge grows (a 19 mm tube with the crest at 1.14 × ID gives 1.33 mm): print that zone with fine layers. A 45° chamfer under the ledge also solves it, but the back face stops being a step and holds less (Orientation and overhangs). Tip down, like the inlet of the example's Y, the ramp becomes a gentle overhang and the back face points up; it only stands on a small footprint.

Upright, tip upSeam = leak path0.6 mm downward ledgeSideways tugBreaks along a layer at the rootRoot filletScarf seamBuild ZLying downOval section with a flat on the bedChannels crossing the sealY with outlets at ±30°30° (≤ 45°)
Upright, the layers ring the barb parallel to the seal line; the seam and a sideways tug are its two weak points. Lying down, it comes out oval and the layers cross the seal. A Y with the outlets at 30° keeps all three barbs nearly upright.

Lying down, the barb comes out oval, with a flat against the bed, and the layer lines run along the axis, crossing every seal line. Each valley between layers is a channel for water to escape. It is the same reason a hole printed horizontally leaks under an O-ring (O-ring grooves).

Tilted, like the outlets of the Y, it sits in between. At 30° from vertical each layer cuts the barb in an ellipse, and the steps cross the seal line slightly: with 0.2 mm layers, the step is about 0.1 mm. That is fine for low pressure, but it is worse than upright: use fine layers on the ridges.

The seam is the printed equivalent of a molding's parting line, and it is a leak path. Good manufacturers stop the parting line at the base of the barb for exactly this reason. In a print, the Z seam is a vertical line of zits and gaps, where every loop starts and ends, crossing every crest. As of late 2026, OrcaSlicer, Bambu Studio and PrusaSlicer (from 2.9) offer a scarf seam, which spreads the start and end of each loop over a short ramp instead of a step: try it first. If you do not have it, align the seam and remove the zit with a blade or a file on the ramp and the plain shank, without touching the back edge of the crest: sanding it rounds it, and that is the edge that seals. The seam modes are in Where the seam goes.

Printing it upright has a price: the barb works as a cantilever with its layers perpendicular to the bending, and if you lever it sideways it snaps flat along a layer at the root. Why it breaks that way is in Layer orientation for mechanisms. Keep it short, about 1.5–2 times the plain-shank diameter, with a root fillet; if it will take side tugs, check it with the worked example's sum and support the tube close by so it cannot lever. If the barb has to take a significant side load, buy a brass or nylon barb and screw it into a printed boss: the metal takes the bending and the printed part only holds it. The thread for that boss is in the next section.

On the barbed section, 0.12–0.16 mm layers leave a sharper edge; limit them to that height with a modifier (Modifiers by region and height). Wall count, flow and infill for a body that does not weep are in Watertight printed parts.

For water, PETG is the reference material, for its heat margin and because it handles water well. PLA only for cold water and light use. ASA or polycarbonate for warm water. PP resists chemicals well but is hard to print. If the part touches drinking water, food or fish, read Printing for food contact: watertight does not mean food safe, and if you buy brass barbs, make them lead-free brass. For fuel, solvents or oils, check the plastic's compatibility in Heat, cold, sunlight and chemicals.

Threaded fittings and adapters

The other end of a barb usually screws into a pump, a filter, a valve or a tap. The rule is a parallel thread with a flat washer or an O-ring on the face, and never a tapered metal thread in a printed female: it wedges and splits it. G, R and NPT threads are developed in Pipe threads and plumbing, and the printed face washer in Printed TPU gaskets.

Threads commonly found next to barbs (ISO 228-1)
Thread Major diameter Threads per inch (pitch) Where it turns up
G 1/4 13.157 mm 19 (1.337 mm) PC cooling blocks, small pumps
G 1/2 20.955 mm 14 (1.814 mm) taps and valves
G 3/4 26.441 mm 14 (1.814 mm) taps and valves

Print G 1/4 only for hand tightening and with layers of 0.16 mm or less. Do not print G 1/8 (0.907 mm pitch): cut the female with a tap or use a brass part. Most threaded brass or nylon barbs on sale have a tapered thread, R (BSPT) or NPT; for a printed boss, look for a parallel G male with a face seal.

Reducers, tees, Ys and elbows apply the same rules to each end, each sized for its own tube. On a part with several outlets, orient the design so every barb sits within 45° of vertical, like the Y in the example, or print the body flat and screw in bought barbs.

Luer tapers on syringes and dispensers (ISO 80369-7) and push-fit fittings for rigid tube are bought, and what you print is the holder: a Luer is a medical connector, and the collet and seal of a push-fit cannot be printed. The 4 mm ones for PTFE are in Push-fit fittings and PTFE tube.

When it fails

What usually goes wrong with a printed barb
Symptom Cause Fix
Drips in a line along the barb Seam crossing the crests, or barb printed lying down Scarf seam, or aligned with the zit removed; axis vertical
Drips round the crest Too little stretch or a rounded crest (thick layers, an oversize barb that was sanded) Crest at 1.15 × measured ID, fine layers on the ridges, stepped back face
Will not go on, or splits the silicone tube Too much stretch (4 mm tube on a 3/16″ barb) or a steep ramp Measure the ID, stretch from the table, 10–15° ramp
Comes off under pressure or heat Tube that has lost its elasticity (cold PVC, reused tube) or pressure above p_c Clamp behind the last ridge; new tube; threaded fitting
The clamp makes it drip It sits over the crest, or overtightens a soft tube Move it to the plain shank; a wide worm-drive clamp instead of a cable tie
The barb snaps flush with the collar, along a layer Cantilevered barb, layers perpendicular to the bending, under a sideways tug Short barb, root fillet, narrower bore, tube supported; or a brass barb screwed into the part
Weeps through the body Porous wall Watertight printed parts

How to test it

Start with a coupon: three barbs in the same print, on a small base, with the crest at 1.10, 1.15 and 1.20 × ID. Push your tube onto each and keep the one that goes on with a firm push by hand and does not turn freely. The method is in Test coupons.

To find leaks, use water and never compressed air at working pressure: air stores energy and, if the part fails, it bursts and throws fragments. Fill it with water, leaving no air inside, and raise it to 1.5 times the working pressure for 10–15 min (common practice, not a standard). With dyed water and kitchen paper you can see where it weeps. If the water shows up in a line along the barb, it is the seam. If it shows round the crest, there is too little stretch or the edge is rounded. If it comes through the body, it is the wall. On small parts, low-pressure air from a syringe or a rubber bulb (a few hundred mbar), with the part under water, shows the leak as a stream of bubbles.

Then pull the tube by hand along the axis and lever it sideways the way the user would. Watch whether the root whitens: that is the layer starting to give.

Finally, time: 48 h in service and another check after a few hot days (Testing a mechanism before you trust it). Silicone and PVC relax, and PLA creeps in the heat.

See also

Design it in KapyCAD

Model the joint with these dimensions. Each one stays a value you can change after the first test print.

Free plan, no card. Runs in your browser, nothing to install.

Open the editor

Still have a question?