kapy academy

Pipe threads and plumbing

17 min readUpdated Nov 2026

Taps, stop valves, filters and tank outlets in most of the world carry BSP threads (British Standard Pipe, 55° Whitworth profile); equipment made in the United States carries NPT, at 60°. The name ("1/2 inch") matches no diameter you can measure. Before you model, identify the letter (G, R or NPT) and model from the table, never from the fraction. Print only the parallel G thread and leave the sealing to a washer on the face.

The name is not a dimension

"1/2 inch" is a trade size (DN15) inherited from the bore of old thick-walled steel pipe. It is neither the thread diameter nor the outside of the pipe. A 1/2 steel pipe is Ø21.3 outside, and its G 1/2 thread has a major diameter of 20.955. Neither is 12.7. Model "half an inch" as 12.7 mm and nothing will fit.

The same name does not guarantee the same pipe either. A European 20 mm PVC pressure pipe and an American 1/2″ Schedule 40 PVC pipe (0.840″ = 21.3 mm outside) are not interchangeable. Copper (EN 1057) is named by its outside diameter: 15, 22, 28. So is multilayer pipe: 16, 20, 26. The thread only appears on the fitting at the end. Always name the thread by its letter and size: G 1/2, R 1/2, 1/2-14 NPT.

:::figure{id="pipe-size-names" caption="To scale: the name "1/2" is none of these diameters, and pipes with the same name do not measure the same."}

  • steel: DN15 "1/2" steel pipe, Ø21.3 outside
  • bore: Bore
  • threadMajor: G 1/2 thread, major Ø20.955
  • notThis: 12.7 mm: not a pipe dimension
  • pvc20: PVC pressure pipe, Ø20
  • sch40: 1/2″ Schedule 40 PVC, Ø21.3
  • copper15: Copper, Ø15
  • multilayer16: Multilayer, Ø16
  • sameName: Same name, different pipe :::

BSP: G parallel, R tapered

BSP threads (sources: ISO 228-1 for G; ISO 7-1 and EN 10226 for R, Rp and Rc; values via en.wikipedia.org/wiki/British_Standard_Pipe)
Size Threads per inch Pitch (mm) Major Ø (mm) Minor Ø (mm) R gauge length (mm) Printable?
1/8 28 0.907 9.728 8.566 4.0 No: pitch under 1 mm. Tap the female thread or use a brass adapter
1/4 19 1.337 13.157 11.445 6.0 Hand-tight only, with fine layers (≤ 0.16 mm)
3/8 19 1.337 16.662 14.950 6.4 Hand-tight only, with fine layers (≤ 0.16 mm)
1/2 14 1.814 20.955 18.631 8.2 Yes, axis vertical
3/4 14 1.814 26.441 24.117 9.5 Yes, axis vertical
1 11 2.309 33.249 30.291 10.4 Yes, axis vertical
1 1/4 11 2.309 41.910 38.952 12.7 Yes, axis vertical
1 1/2 11 2.309 47.803 44.845 12.7 Yes, axis vertical
2 11 2.309 59.614 56.656 15.9 Yes, axis vertical

The last column applies the minimum printable pitch from Modeling threads: 1 mm with a 0.4 nozzle. The R 1/8 on push-fit fittings has its own article, Push-fit fittings and PTFE tube.

The profile has a 55° included angle, rounded crests and roots (r ≈ 0.137 P) and a depth h ≈ 0.640 P (1.16 mm on G 1/2). A printed part does not need the rounding: a flat crest prints better and does not bother the bought part, as long as your depth stays below h.

The letter tells you the form. G is parallel, male or female (ISO 228). R is a tapered male; Rp a parallel female; Rc a tapered female. All three are ISO 7. The taper is 1:16 on the diameter (a half-angle of 1° 47′). In Europe the female is nearly always Rp and the male R: the taper on the male is enough to wedge.

What matters is where each one seals. ISO 228 states that a G thread is not pressure-tight on the threads: the thread only clamps; the lip, the rim or the gasket does the sealing, here a flat washer or a squashed O-ring between the end face of the male and the seat of the female. The ISO 7 R thread seals on the flanks: PTFE tape, hemp with paste or anaerobic sealant fills the helical path the water would otherwise follow. Taping a G thread is no substitute for the washer. Bottle necks, jars and garden taps follow the same rule as G.

Parallel (G 1/2)MaleLeak path: the threaddoes not seal itFemaleSeals hereFlat washerMajor Ø20.955Tapered (R 1/2 in Rp female)Taper 1:16Each turn: +P/16 on thediameter (0.113 mm on1/2)MaleWedgeHoop stress in thefemaleSeals hereSealant on the flanksFemale55°Pitch 1.81455°60° (NPT)
G seals at the washer on the face; a tapered thread seals on the flanks, with sealant and by wedging.

NPT: why it does not mix with BSP

NPT threads (source: ASME B1.20.1, values via en.wikipedia.org/wiki/National_pipe_thread)
Size Threads per inch Pitch (mm) Pipe outside Ø Hand-tight engagement L1 (turns) Effective thread L2 (turns)
1/8 27 0.941 0.405″ (10.3 mm) 4.36 7.13
1/4 18 1.411 0.540″ (13.7 mm) 4.10 7.23
3/8 18 1.411 0.675″ (17.1 mm) 4.32 7.34
1/2 14 1.814 0.840″ (21.3 mm) 4.48 7.47
3/4 14 1.814 1.050″ (26.7 mm) 4.75 7.64
1 11.5 2.209 1.315″ (33.4 mm) 4.60 7.85

NPT has a 60° included angle with flat-truncated crests and roots, and it is always tapered (1:16, like R). It seals on the flanks with sealant. NPTF is the dry-seal variant: its crests interfere and it needs no sealant. The diameter column gives the outside of the American pipe the thread is cut on.

At 1/2 and 3/4 both systems have 14 threads per inch, so an NPT male goes into a BSP female, wedges after two or three turns at the wrong angle, feels tight and weeps along the flanks. In the other sizes the pitches differ: 27 against 28 at 1/8, 18 against 19 at 1/4 and 3/8, 11.5 against 11 from 1″ up. The mix binds within a few turns, sooner the more the pitches differ.

In Europe, NPT tends to turn up on American-made pumps, pressure washers, reverse-osmosis and aquarium equipment and some compressors. Read the label or measure; do not assume. To join the two systems, buy a brass NPT × BSP adapter; do not print a thread halfway between them.

How to tell which thread you have

The general method for measuring is in Measuring an undocumented standard. This is what is specific to pipe threads:

  1. Major Ø. Measure it with callipers on the male, or on the crests you can see inside the female. 20.9–21.0 is 1/2; 26.4 is 3/4; 33.2 is 1 in BSP. On a tapered thread the diameter changes along the length: measure on the first full thread.
  2. Pitch. Use a thread gauge, or count crests over whatever length there is and scale to 25.4 mm: at 1/8 and 1/4 the male is under 10 mm long. 14 is 1/2 or 3/4 in both systems; 19 is BSP 1/4–3/8; 18 is NPT 1/4–3/8. Telling 11 from 11.5 takes a gauge.
  3. Taper. Measure the major Ø on the first and the last full thread. 1:16 over 10 mm of thread is 0.6 mm on the diameter: callipers show it clearly. If the diameter does not change, it is G (or Rp, if female). If it shrinks toward the tip, it is R or NPT.
  4. Angle. It only matters if you counted 14 threads. A 55° gauge leaf sits with no light showing on BSP and shows light on NPT. Without a gauge, the best clue is where the equipment came from.
  5. Hose. American hose thread (GHT, 11.5 threads per inch) falls in the same diameter range. If you count 11.5 on a Ø26.5–27 garden fitting, go to Garden hose threads.
diagram
Diameter and pitch first. In BSP, the taper separates G from R; you only need the angle at 14 threads, the pitch both systems share.

What to print and what not to

Print the parallel G thread and make the seal on a face. A printed G female on a bought brass male (or the other way round), with a flat washer or an O-ring on the face, is the reliable combination. Layer roughness on the flanks no longer matters: the water does not go that way.

Do not print a sealing tapered thread (R or NPT) to tighten against metal. The wedge is the whole point of the taper, and it is what splits a printed female: the usual spanner tightening stretches it to the limit of what the plastic will take (Print-friendly snap fits), and creep does the rest.

With the axis vertical, that stress runs along the beads of each layer and the female opens along the vertical seam; with the axis horizontal, it splits along a layer. If it does not break, it loosens. The other way round, a printed tapered male in a metal female crushes its own crests.

If a bought R male has to go into a printed part, make the female parallel: Rp has the same basic diameters as G and, for modeling purposes, is opened up as in the example below. Put a washer on the face, under the collar of the male, and go no further than hand-tight plus a quarter turn. On a printed parallel thread, PTFE tape does not seal: it lubricates, and you end up overtightening. Keep it for metal-to-metal R or NPT joints.

For drinking water, the material and the layer lines decide; see Printing for food contact. Watertight walls are in Watertight printed parts. In a 1/2 pipe printed with a 3 mm wall, at 5 bar, the stress in the wall is about 2 MPa, an order of magnitude below what the plastic will take: porosity and creep set the limit (Watertight printed parts). Keep the seam away from the loaded side.

Example: G 1/2 female adapter with a flat washer at 4 bar

Goal: a PETG adapter that screws onto a brass G 1/2 male (the outlet of an outdoor ball valve) and carries a nozzle or a hose barb at the other end. It works at 4 bar, with the valve shut when not in use.

1. Measure the male. Major Ø ≈ 20.9, 14 threads per inch, constant diameter (G, not R). Measure the length of thread on the brass (say, 12 mm) and the width of the flat end face, where the washer will sit.

2. Open up the female. Against a metal male, all the clearance goes on the printed part: 2 × Δr on the diameter, 0.40 mm on a modern bedslinger (Modeling threads): 20.955 + 0.40 → Ø21.35 at the root of the printed thread.

3. Thread. Apply the "Thread" tool to the hole (Threads): pitch 1.814, depth 1.0, flank 27.5° (half of 55°), right-handed and single-start. A depth a little under h = 1.16 leaves a flat crest and clearance at the root; with the full h, as in Garden hose threads, open up the minor diameter as well. The hole you model is 21.35 − 2 × 1.0 = 19.35. Make the printed thread 9 mm long and chamfer the mouth at 0.5 × 45°. Below the thread, leave a plain Ø21.35 section down to the seat, so the tip of the male can pass.

4. Seat and washer. At the bottom, a flat seat with a shallow recess that centers a 1/2 EPDM flat washer about 2 mm thick, or an O-ring in a face groove (O-ring grooves: static face squeeze ≤ 30 %). Avoid fiber washers: they barely compress and need a torque that a hand-tightened printed female cannot deliver. The washer goes in through the thread, so its outside Ø has to be under 19.35. 1/2 tap washers tend to be around 18–19 mm: measure yours.

5. Travel. A 25–30 % squeeze is 0.5–0.6 mm, about 100–120° of rotation at 1.814 pitch from the moment the male touches the washer. There is no glass rim to bottom out on here, as there is on a jar: the face of the male does the squashing, so tightening sets the squeeze, and hand-tight plus a quarter turn is enough. The model only has to leave enough travel: the distance from the mouth to the face of the squashed washer must be at least 1 mm less than the thread on the brass. With the seat 11 mm from the mouth, the squashed washer sits at about 9.6 mm, against 12 mm of thread on the brass: 2.4 mm to spare before the brass thread runout reaches the mouth.

6. Loads. Pressure pushes the male out with F = p · π/4 · D². With D ≈ 19 (the outside of the washer, where it seals): 0.4 MPa × 284 mm² ≈ 115 N, about 140 N at 5 bar. Add the preload that squashes the washer, of the same order or larger, which does not go away when you shut the valve: the design load is the sum of the two, and it is always applied. The threads carry it with room to spare. The weak point is the bottom of the female, loaded in Z: count on half the XY strength (Layer adhesion and anisotropy), about 17 MPa in PLA and 25 in PETG. Print the adapter axis vertical with the mouth up, 4 walls and a 2 mm fillet where the bottom meets the wall.

7. Material. PETG over PLA: in the sun the part warms up, and under load PLA works up to about 40 °C and PETG up to 50. ASA if it sits in full sun (Heat, cold, sunlight and chemicals).

Pipes: outside diameters and drains

Pipe outside diameters (sources: EN ISO 1452; EN 1329-1, application area B; EN 1057; EN 10255; US NPS nominal sizes)
Pipe Named by Common outside diameters (mm)
PVC-U pressure (EN ISO 1452) Outside Ø 16, 20, 25, 32, 40, 50, 63…
PVC-U soil and waste inside buildings (EN 1329-1) Outside Ø 32, 40, 50, 75, 90, 110, 125, 160…
PE irrigation Outside Ø 16, 20, 25, 32
Copper (EN 1057) Outside Ø 15, 22, 28
Multilayer Outside Ø 16, 20, 26
Steel (EN 10255) DN (trade size) DN15 = 21.3 · DN20 = 26.9 · DN25 = 33.7
PVC Schedule 40 (US) NPS (inches) 1/2″ = 21.3 · 3/4″ = 26.7 · 1″ = 33.4

A printed sleeve over a bought pipe takes as its bore the measured outside of the pipe, not the nominal, plus your sliding clearance for a printed hole on a bought shaft, counted on the diameter (twice the per-side value; Real printed clearances). Print it axis vertical.

PVC solvent cement is made to join PVC to PVC; do not count on it to bond PLA or PETG. Get the seal mechanically, with an O-ring in a radial groove (O-ring grooves) or a TPU sleeve (Printed TPU gaskets), and hold it with a hose clamp, or bond it with epoxy.

Drains are the most forgiving plumbing to print: they work at atmospheric pressure. Overflow plugs, condensate traps, rain-tank diverters, 40-to-32 reducers. With one exception: a washing machine or dishwasher drain carries hot water, 60 °C or more on the hot programs, which softens PLA and warps PETG. For an adapter from its hose to the 40 mm waste, use ASA or PC. Workshop dust-extraction adapters, which use these same diameters, are in Dust-extraction adapters.

When it fails

Pipe threads: symptom, cause and fix
Symptom Cause Fix
Goes in a few turns and binds Thread from the other system (NPT in BSP, 11 against 11.5) or a tapered R in your parallel female Measure the pitch and the taper; buy a brass adapter
Leaks along the thread The seal relies on the thread Flat washer or O-ring on the face; tape does not fix a printed G thread
Leaks at the face The male bottoms out before squashing the washer, or the washer is too hard (fiber) Bring the seat closer to the mouth or shorten the printed thread; EPDM washer
Weeps through the wall Porosity More perimeters and a little more extrusion flow (Watertight printed parts)
Splits along the vertical seam or along a layer Wedging from a tapered thread or spanner tightening Parallel female, hand-tight plus a quarter turn; seam away from the loaded side
Loosens after a few weeks Creep of the washer and the plastic under constant pressure or heat PETG or ASA; never on hot water; shut the valve when not in use

How to test it

Hand-tighten and add a quarter turn. Open the valve over a bucket and leave it 10 minutes at mains pressure: not a drop should fall from the face and no water should weep through the walls. After 48 hours, open it again and check it is still tight: the washer and the plastic relax.

See also

Design it in KapyCAD

Draw the part to the standard's dimensions and keep them as values you can edit.

Free plan, no card. Runs in your browser, nothing to install.

Open the editor

Still have a question?