kapy academy

Clips for tubes and cables

15 min readUpdated Nov 2026

You want to run a cable down a table leg or a tube along the printer frame or a wall: push it in by hand, have it stay and take it out one day without breaking the clip. A round part is a ramp in both directions: the circle that opens the clip on the way in opens it on the way out too, so a plain C clip comes off with almost the force it took to go on. That force and the plastic's strain depend on how far the mouth opens and how hard the ring is to spread.

Three ways to hold something round

Which retainer to choose
Form How it holds What for
C clip An open ring, mouth on top, wrapping more than 180° of the part; the whole ring flexes One cable or tube, fitted by hand
U clip Two straight arms with an inward lip at the mouth; each arm is a cantilever Rigid tubes, small diameters, combs for several cables
Cable-tie anchor The tie does the clamping; the printed plastic is not a spring Harnesses, vibration, runs you will not take apart

Soft, loose cable: C clip. Rigid tube or rod: C clip with a free ring, or U clip. Harness or permanent fitting: cable-tie anchor. Metal retaining rings (DIN 471 for shafts, DIN 472 for bores) are a different thing: this is about printed clips that hold a tube or cable to something.

The C clip: how far it should wrap

Three dimensions define the clip: the inner diameter D (the part plus clearance), the wrap angle θ (how many degrees of the circle the ring covers) and the mouth width w. With θ above 180°, the mouth is w = D·sin(θ/2). For the part to go in, the mouth has to open up to D, so the opening needed is Δ = D − w = D·(1 − sin(θ/2)).

Peak strain sits at the back of the ring, opposite the mouth, because that is where the bending moment from both tips adds up. If the ring is free to open, joined to the base by a narrow neck at the back, the strain is roughly:

ε ≈ k·t·Δ / R²

where t is the ring thickness measured in the direction of bending, R the mean radius (D/2 + t/2) and k a factor that depends on the wrap angle. The formula comes from modeling the ring as a curved beam opened by two equal forces applied at the tips.

C clip by wrap angle
θ w / D Δ / D k Equivalent retention face
240° 0.87 0.13 0.17 30°
270° 0.71 0.29 0.14 45°
300° 0.50 0.50 0.12 60°

The last column is the angle the circle amounts to when you pull the part out; "Retention", further down, explains it.

Below about 220° the part falls out on its own. From 300° on, the mouth has to open by half a diameter and the retention face approaches the locking angle: you can no longer count on getting it off. Strain rises with t and falls with R², because a large ring spreads the bending over a longer arc. At a fixed angle, ε is proportional to t/D: gripping a thin cable is harder than gripping a thick tube, and a thinner ring is what helps most.

Compare ε with what the material allows. In repeated use PLA takes 1–1.5 % strain (1 % if it opens daily) and PETG 2 % (Print-friendly snap fits); in a one-off assembly, 2 % and 3–4 %. Fiber-filled filaments take less repeated strain than PLA: they are not for springs, flexures or snap arms (Which plastic for which mechanism).

The force comes from the same beam. Each tip pushes with F ≈ ε·E·b·t² / (6·R·(1 + cos α)), where b is the clip width along the part and α = 180° − θ/2. Width raises the force without touching the strain: if the clip grips too lightly, make it wider before you make the ring thicker.

Retention. When you pull, the contact at the tip acts like a retention face inclined θ/2 − 90° to the pull axis: 30° at 240°, 45° at 270°, 60° at 300°. A retention face only locks from about 63–73° (with μ between 0.3 and 0.5; Snap-fit catches). Up to 300°, then, a C clip does not lock: a firm pull always gets it off, which is why it can be removed. The more it wraps, the more it holds and the harder it is to fit.

Lead-in lip. Flare the tips outwards in a 25–35° ramp to the insertion axis. Going in, the part meets a gentle ramp; coming out, it meets the steep circle. Fitting gets easier and removal stays as hard as before. At around 240° the bare tip already gives a lead-in of about 30°; above about 250° the entry steepens, and without a lip the clip is hard to push on.

Neck. Join the ring to the base with a narrow neck, about 1.5·t, so the back can bend: the k table assumes it. A neck a third of D wide already stiffens the back and raises strain by 40 %. If the ring is joined to a solid block up to its centerline, only the upper arcs flex and the strain multiplies. Fillet the ring-to-neck joint with r ≈ 0.5·t.

wMouthPushDRθWrap angletΔ/2RetentionLead-in lipRingPeak strainPartOpenedNeckBaseWrap angleRetentionw240°30°w270°45°w300°60°
Left: a C clip on a part of diameter D. As you push, the mouth w opens by Δ; peak strain sits at the back, above the neck. The lead-in lip flares the tips, and the equivalent retention face lies θ/2 − 90° from the pull axis. Right: the same part with 240°, 270° and 300° of wrap.

Worked example: a Ø16 PVC conduit and a Ø6 cable

Ø16 rigid PVC conduit has a tolerance of +0/−0.3 mm (EN 60423, the dimensions standard for EN 61386 conduit): it is never above its nominal size. Wall clip in PLA, ring t = 2.0 mm (5 lines at 0.4 mm), 3 mm neck and a 16.0 hole in the model, with no clearance. The conduit is that size or smaller and the printed hole comes out a little small, so it grips. R = 8 + 1 = 9 mm.

At θ = 270°: Δ = 0.29 × 16 = 4.7 mm and ε ≈ 0.14 × 2.0 × 4.7 / 81 ≈ 1.6 %. That is under PLA's 2 % for one-off assembly, but above the 1–1.5 % for repeated use. Fine for a conduit you fit once and leave; in PETG (2 % repeated) you can take it off and put it back as often as you like. With b = 10 mm and PLA's design E of 2.5 GPa, each tip pushes with about 17 N; in PETG (1.6 GPa), with about 11 N.

At θ = 240°: Δ = 0.13 × 16 = 2.1 mm and ε ≈ 0.17 × 2.0 × 2.1 / 81 ≈ 0.9 %. Comfortable in PLA even with daily use, with less grip: 30° of retention instead of 45°.

Now a Ø6 power cable with the same 2.0 mm ring at 270°: R = 4, Δ = 1.76 and ε ≈ 0.14 × 2.0 × 1.76 / 16 ≈ 3 %. PLA cracks and PETG is at its one-off limit. The fix is t = 1.2 mm (3 lines, the minimum for a flexing arm) and θ = 240°: R = 3.6, Δ = 0.80 and ε ≈ 0.17 × 1.2 × 0.80 / 13 ≈ 1.3 %.

Soft cables and hard tubes

A cable jacket is soft: it squashes in the mouth and takes up part of Δ, so a cable clip tolerates geometry that would crack the ring on a rigid tube. How much it takes up varies from cable to cable; measure yours with callipers. A PTFE tube, a rod or an installation conduit gives nothing: the ring takes the whole opening Δ and the formula applies in full.

The hole clearance decides what the clip does. With a sliding fit (0.20 mm per side, 0.40 on the diameter) the cable or tube slides through and the clip acts as a guide. With no clearance, or a friction fit (≈ 0.10 mm per side), the part does not slide along the clip. A small hole printed vertically loses 0.1–0.3 mm of diameter (Why holes print small): print a coupon and measure it before you trust the model dimension (Test coupons).

The parts these clips hold most often are 4 mm OD Bowden PTFE tube (Push-fit fittings and PTFE tube), and rigid PVC conduit, with 16 to 32 mm the most common sizes in Europe. For everything else (USB, mains cables, hoses), measure: two cables of the same type can differ by up to a millimeter.

The U clip: straight arms

Two straight arms of length L rise from the base and end in a lip that projects inwards. Each arm is a cantilever, with the formula from Print-friendly snap fits: ε ≈ 1.5·t·y/L², with L ≥ 5·t and a fillet of r ≈ 0.5·t at the root.

It beats the C clip on small rigid parts because the arm length does not depend on the part radius, and strain falls with L². For a Ø6 rigid rod in PLA, with t = 1.2, y = 0.5 per side and L = 10: ε ≈ 1.5 × 1.2 × 0.5 / 100 = 0.9 %.

The lip has a 25–35° lead-in face and a retention face you choose, measured from the insertion axis: 30–45° lets go, 80–90° is permanent. Unlike the C clip, the retention angle here is free: you can make a U clip that does not come off.

For several cables, make a comb: a row of U slots, each with its own width. If a thick cable and a thin one share a slot, the thin one falls out.

How to print it

Apply the rule from Layer orientation for mechanisms: the beam's length has to lie in the layer plane, so the strain runs along the beads. A C clip with the ring drawn in XY (the part's axis vertical, the clip lying on its side) has a ring made entirely of walls flexing in the layer plane. That is stance B (bending within the layer plane), the best one, and the hole, vertical, comes out round. Keep the seam away from the back of the ring, where peak strain sits.

In a C clip standing on its base, with the part's axis horizontal and the ring in a vertical plane, the sides of the ring rise in Z. At 3 and 9 o'clock the strain crosses the layers (stance C, bending across the layers) and the ring splits along a layer, because the bond between layers is about half as strong as the material in XY (Layer adhesion and anisotropy). It is the usual case when the clip is part of a larger part printed flat. If you cannot turn it, limit strain to half the allowable (for PLA, 0.5–0.75 % in repeated use), use PETG or PA and widen the clip along the part (more force, same strain). If that is still not enough, print the clip separately and screw it on, or switch to an anchor with slots.

The same goes for the U clip. Draw the U profile in XY and extrude it upwards: both arms flex in the layer plane (B). Standing on a face, with the arms rising in Z, it is stance C.

BedB: ring in the layer planeZC: sides in Z, splits between layersCrackLayersZBedU: arms in the layer planeZ
Orientation decides whether the clip survives. With the ring drawn in the layer plane (B), all of it flexes along the beads. Standing on its base (C), the sides rise in Z and split along a layer at 3 and 9 o'clock. A U clip with its profile drawn in the layer plane also works in B.

Cable-tie anchors

An anchor is a bridge over a face that the cable tie threads through. The tie does the clamping; the printed bridge only has to take its pull. Cable ties are rated by loop tensile strength: a 2.5 mm wide tie is usually 18 lb (about 80 N) and a 3.6 mm one 40 lb (about 180 N). The usual widths are 2.5, 3.6, 4.8 and 7.6 mm, but thickness and strength vary between manufacturers: measure yours. Any of them is stronger than a small anchor: pull hard and the anchor gives before the tie.

The tunnel is as wide as the tie plus two clearances, and as high as its thickness plus one clearance (0.3 mm works well). The roof is a short bridge that prints cleanly without supports with the face up: a span of about 5.4 mm for a 4.8 tie, a little over 8 for a 7.6. If it sags, see Overhang and bridge settings. Give the roof at least 4 layers.

With the face up, the tie pulls the roof vertically and the posts work in tension across the layers (stance C). For a cable someone is going to tug on, thicken the posts and widen the bridge, or use the stronger alternative: two slots through a plate or wall, with the tie wrapped around a solid web of the part. That way no layer bond works in tension.

Cable tieCable tiePullw + 2ct + cClearanceTunnelPostRoofCablePartTension across layersPullWebSlotsCableCable tiePart
Left: an anchor's tunnel is as wide as the tie plus two clearances, and as high as its thickness plus one; under a pull, the posts work in tension across the layers. Right: two slots through the plate; the tie wraps around the web and the pull loads it in the layer plane.

When it fails

Symptom → cause → fix
Symptom Cause Fix
Cracks at the back the first time it goes on Strain above the one-off limit: too much wrap, thick ring, small D Drop to 240°, 1.2 mm ring, PETG; recalculate ε
Splits at the sides, along a layer Ring printed vertically (stance C) Draw the ring in XY, or PETG/PA at half the strain
Hard to push on and comes off with similar force No lead-in lip Flare the tips at 25–35°
The part falls out on its own Less than about 220° of wrap, or a loose hole More wrap, or a friction fit
The tube slides along the clip Sliding fit in the hole No clearance or a friction fit; measure the printed hole
Loses grip over the weeks, worse when warm Creep under constant squeeze; under load, PLA only holds up to about 40 °C PC or ASA, or PETG if the problem is heat (up to about 50 °C under load); less squeeze (Creep and fatigue)
The anchor roof tears off its posts The tie's pull loads the layers in tension Wider bridge, thicker posts, or two slots in the wall
The tie will not go through Tunnel without enough clearance: printed gaps come out small 0.4–0.5 mm clearance and a chamfer at the tunnel mouths

How to test it

Print a strip of three clips at 240°, 260° and 280° and try them on the real tube or cable. Push each one on and off 20 times and look at the back. PETG and PP whiten before they break: if it whitens, you are close to the limit. PLA gives little warning; look for microcracks at the back.

For pull-out force, hang a known weight from the part or measure the pull with a luggage scale. Check the grip again after 48 hours with the clip fitted; Testing a mechanism before you trust it covers the force-travel curve and the creep test. On the anchor, pull the tie by hand harder than anyone will ever pull the cable: you are testing the anchor, not the tie.

See also

Design it in KapyCAD

Model the joint with these dimensions. Each one stays a value you can change after the first test print.

Free plan, no card. Runs in your browser, nothing to install.

Open the editor

Still have a question?