A fan rated at 8 m³/h in free air can move half that, or almost nothing, through a badly drawn grille. What you print around the fan (the panel with its hole pattern, the grille, the filter frame and the duct adapter) decides how much air actually gets through. Size the flow from the heat you have to remove, count on half the rated figure, and give the grille 70 % open area or more. Which fumes a printer gives off and which filter catches them is covered in Emissions and ventilation.
The dimensions
Square axial fans come in a handful of frame sizes, and each size has its own spacing between the four holes. No standard publishes it, but Delta's and Noctua's drawings agree, so a pattern drawn from the table below fits any brand of that size.
| Frame | Hole spacing (center to center, on a square) | Hole Ø on the drawing | Most common depths |
|---|---|---|---|
| 25 | 20 | 2.8 | 10 |
| 30 | 24 | 3.2 | 10 |
| 40 | 32 | 3.5 | 10, 15, 20 |
| 50 | 40 | 4.3 | 15 |
| 60 | 50 | 4.5 | 15, 25 |
| 70 | 61.5 | 4.3 | 15 |
| 80 | 71.5 | 4.5 | 25 |
| 92 | 82.5 | 4.5 | 14, 25 |
| 120 | 105 | 4.5 | 15, 25 |
| 140 | 124.5 (some, 125) | — | 25 |
Source: spacings from Delta's drawings (AFB and ASB series) and Noctua's datasheets; hole Ø from Delta's drawings; the 140 mm from the Noctua NF-P14s datasheet. Drawing tolerances: frame ± 0.5; hole spacing ± 0.3; hole Ø ± 0.3. "25 mm" deep fans actually measure 25.4 ± 0.5 (one inch). Other depths exist (server fans, slim models): the list is not exhaustive.
The 61.5 on the 70 mm fan looks like a typo, but it is the dimension on Delta's drawing. 200 mm fans have no common pattern; 154 is frequent, but measure yours. If the frame has more than four holes, measure the spacing between the ones you will use. Centrifugal printer blowers (4010, 4020 and 5015 in their radial form) have no common pattern: measure yours or work from its drawing. Axial 40 × 10 and 40 × 20 fans do follow the 32 pattern.
The 80, 92 and 120 fans have two flanges, one on each face, with four holes in each: eight in all. The flanges are 4 mm thick on the 80 and the 92, and 5 mm on the 120. That thickness sets the screw length: if you screw through the front flange, the screw grips only 4 or 5 mm of frame. From 25 to 70, the drawing dimensions a single set of four holes, with flanges of 2 to 3 mm (2.5 on the 40). On the 70, Delta also draws a Ø6.5 counterbore, 6 mm deep, for the screw head: measure yours.
No manufacturer's drawing specifies the screw. In practice, PC case fans take short coarse-thread self-tapping screws (about 5 mm) that cut their own thread in the frame hole, or long M3, M4 or #6-32 screws with a nut that pass right through a 25 mm frame. Fans of 40 mm and smaller use M3 (M2.5 on the 25 and 30). That is habit, not a standard: check the screw that comes with your fan before you draw the panel.
The frame carries two molded arrows: one shows the airflow direction, the other the direction of rotation. On almost every axial fan, air leaves through the face with the struts that hold the motor, the one with the label. If the arrows and the label disagree, trust the arrows.
How much air an enclosure needs
The flow you need depends on the heat you have to remove: Q = P / (ρ · cp · ΔT), where P is the power dissipated inside, ρ the density of air, cp its specific heat and ΔT the rise in air temperature you accept between inlet and outlet. For air at sea level, ρ · cp ≈ 1200 J/(m³·K), and the formula reduces to:
Q [m³/h] ≈ 3 · P [W] / ΔT [K]
ΔT is set by the weakest material in the enclosure. Under load, an unfilled part works up to about 15–20 °C below its HDT at 0.45 MPa: PLA about 40 °C, PETG 50, ASA 80–85 (Heat, cold, sunlight and chemicals). With the room at 25 °C, a PLA enclosure has 15 K of margin at most; next to the components the air is hotter than the average, so design for about 10 K.
Why it never reaches its rated flow
A fan has a falling curve: the more pressure it works against, the less air it moves. The enclosure has its own curve, which rises with flow: close to a straight line for meshes and fine filters, with the square of the flow for grilles and bends. The fan runs where the two cross: the operating point. Every grille, every mesh and every bend adds resistance and pushes that point toward less air.
Worked example: a 10 W enclosure
A single-board computer and a regulator dissipate 10 W inside a PETG enclosure. The room is at 25 °C. PETG would tolerate about 25 K, but you want the components to run cool, so you pick ΔT = 10 K, a conservative margin.
- Required flow: Q = 3 · 10 / 10 = 3 m³/h.
- A 40 × 10 such as the Noctua NF-A4x10 FLX gives 8.2 m³/h and 1.78 mm H₂O at full speed (6.6 m³/h and 1.21 mm H₂O with the low-noise adapter it ships with). Those are the two ends of its curve: it delivers 8.2 m³/h only against no resistance at all, and against 1.78 mm H₂O the flow drops to zero.
- With a grille on each side and a dust mesh, the operating point lands between the two. Assume half the rated flow: about 4 m³/h.
- 4 ≥ 3: it works, with little margin. A 40 mm fan is enough for an enclosure of up to about 10 W; above that, move to a 60 or an 80.
The air you push out has to come in somewhere. Give the inlet at least 1.5 times the area of the fan frame and put it low, on the side opposite the outlet, so the air crosses the hot parts. The outlet goes high, because hot air rises. Without an inlet, the fan only stirs the air inside.
An axial fan moves a lot of volume against little resistance. A centrifugal blower gives several times the pressure at a lower flow. To push air through a thick filter bed or a narrow duct, use a blower; on a panel with a grille, an axial.
Grilles that do not choke the airflow
Open area is the free fraction of the opening: free area divided by total area. With an opening c and a bar width b:
- rings, slots and parallel bars: ≈ c / (c + b);
- honeycomb: ≈ (c / (c + b))².
With c = 5 and b = 1.6, rings, slots and bars leave ≈ 76 % open and honeycomb ≈ 57 %. The spokes that hold the rings take off a few points more. Honeycomb is not the most efficient grille: with the same bar, it puts the most plastic in the way.
Measurements bear this out: a hexagonal grille with 50 % open area, fitted on the intake of a 120 mm Noctua, cut the flow by around 20 % and added 3.1 dB(A); a round wire grille cost 0–2 % and 0.5 dB(A) (HWCooling's measurements). Aim for 70 % open area or more.
The center does not blow. The motor hub is about 24 mm across on a 40 mm fan and about 48 mm on a 120: covering that zone costs no flow and gives the grille a stiff center. The opening that matters is the frame bore, about 38 mm on the 40, 77 on the 80 and 114 on the 120. If the panel opening is smaller than that bore, the panel covers the blade tips, which is where most of the air goes.
When the blades pass through the wake of a nearby bar, they produce a tone at the blade-pass frequency. Keep the bars a few millimeters away from the blades (the frame flange already provides part of that gap) and, if you can, put the grille on the outlet rather than the intake, where it is quieter. Screwed rigidly to a thin panel, the fan turns it into a loudspeaker; a TPU gasket or silicone mounts decouple it.
Print the panel face down on the bed: rings and slots come out without supports. Every bar is a printed wall, so give it a whole number of beads: with a 0.4 mm nozzle, three beads make 1.2 mm and four about 1.6 (Walls, perimeters and infill). A one-bead bar is a single wall, and it snaps.
The Ø on the drawing (4.5 on a 120) is the fan's own hole, not the one your panel needs. For a screw to pass through the panel, use its clearance hole (ISO 273 medium series: 3.4 for M3; 4.5 for M4) and compensate it, because printed holes come out small (Why holes print small, Captive nuts and clearance holes). If you use the short self-tapping screws that come with case fans, measure their thread and draw the clearance for it: they will not pass through a 4.5 hole. If you drive a self-tapping screw into a printed boss, the pilot-hole diameter is in Self-tapping screws in plastic.
Filters and duct adapters
A dust filter goes on the inlet: a mesh clamped between the fan and a printed frame, or a frame that slides along a pair of rails. The mesh adds resistance to the system curve. Give it more area than the fan: with a larger filter frame and a plenum behind it, the air crosses the mesh more slowly and the mesh takes longer to clog. With the filter on the inlet, the enclosure sits at a slight positive pressure and dust gets in only through the mesh.
For a bought filter medium (a HEPA sheet, a carbon cartridge), the printed part is a frame with a seat and a seal: air that leaks around the edges is not filtered. Put a TPU gasket or a lip in the seat (Functional multi-material parts). What each medium catches is in Emissions and ventilation: an H13 catches at least 99.95 % of particles at the most penetrating size, and carbon catches volatile organic compounds until it saturates.
As of late 2026 there are open-source printer filters that you print and assemble like a kit. The most widespread is the Nevermore family: pelletised activated carbon in printed cartridges. Its StealthMax adds a HEPA stage.
Where the cross-section grows, an adapter from a square fan to a round duct works as a diffuser. Widen it gradually: a half-angle of 7° at most, ideally 3.5–5°. Beyond about 15°, the transition recovers almost no pressure and behaves like a step: the air separates from the wall and the fan pushes against an eddy. A reducer tolerates 30–45° with small losses, because the air accelerates and does not separate. Two cases:
- 80 fan (77 bore) to a 100 duct: the radius grows by 11.5 mm. At 7° you need about 94 mm of length; at 5°, about 131. At 15° (43 mm) you have already lost almost all the recovery.
- 120 fan (114 bore) to a 100 duct: the radius shrinks by 7 mm. At 45°, the steepest you can print without supports, the transition takes about 7 mm.
Print the adapter standing up, with walls of three beads or more and no overhangs beyond 45°.
European ventilation ducts follow the nominal diameters of EN 1506 (63, 80, 100, 125, 150, 160, 200…). US flexible duct is sized in inches: 4″ is about 102 mm, and it is not the same duct as a 100. Whether the spigot goes inside or outside the duct, and at what exact diameter, depends on the duct: measure it and print a short test ring (Test coupons). A bead and a hose clamp hold flexible aluminum duct better than friction alone. For vacuum hoses, the same measure-and-fit method is in Dust-extraction adapters.
When it fails
| Symptom | Cause | Fix |
|---|---|---|
| The enclosure heats up with the fan running | No inlet, or the inlet next to the outlet: the air leaves without passing the components | Inlet low and on the opposite side, with ≥ 1.5 times the frame area |
| It spins but barely blows | Grille with under 60 % open area, or an opening smaller than the frame bore | Rings or slots, ≥ 70 %; opening equal to the frame bore |
| Whistle or tonal hum | Bars too close to the blades, or on the intake | Move them away or put the grille on the outlet |
| The screws will not pass through the panel | Hole drawn at the fan's Ø, printed small | Screw clearance hole + compensation |
| The panel vibrates | Rigid mounting on a thin wall | TPU gasket, thicker panel or ribs |
| Flow drops within a few weeks | Mesh with the same area as the fan | Larger frame with a plenum; clean it regularly |
| The adapter whistles or chokes the flow | Abrupt widening | Longer transition, half-angle ≤ 7° |
| It blows the wrong way | Oriented by the label, not the arrows | Read the arrows on the frame |
How to test it
Hold a strip of tissue paper at the outlet with and without the grille, or measure the temperature inside the enclosure after 30 minutes at full load. A cheap anemometer at the outlet lets you compare grilles. Before printing the whole enclosure, test the grille on a coupon the size of the frame plus 10 mm per side.
See also
- Emissions and ventilation: which fumes a printer gives off and which filter catches each.
- Enclosures and heated chambers: where the 120-to-100 extraction adapter goes.
- PC form factors and drives: fans in computer cases.
- Enclosure lids: how to close the enclosure that carries the fan.