You let go of a box lid at 60° and it comes down in two or three seconds, and meets the frame without a bang. Behind that is a damper: a part that resists rotation harder the faster it turns. At rest it resists nothing; spun fast, a lot. That is why it slows the fall without holding the lid up. A spring stores energy and gives it back (Spring-return hinge); a damper turns it into heat and gives nothing back, and a gear lets a small one brake a large lid.

Three dampers seen from above and the same lid falling slowly and being lifted again: an orange rotor shearing the blue oil in its gap, with dots showing how each layer drags the next; a toothed sector on the lid turning a damper's pinion four times as fast; and a syringe whose plunger pushes the air out through an orifice and lets it back in through a check valve
The three dampers covered here and where each one dissipates energy: oil sheared in the gap of a rotary damper, a gear damper driven by a sector on the lid, and a syringe pushing air out through an orifice. The same lid drives all three, falling slowly and lifted quickly. The rotary damper's gap is drawn ×13 and the orifice larger than it is.

Braking with speed

A rotary viscous damper obeys T = c·ω (c in N·m·s/rad); a linear one, F = c·v (c in N·s/m). Fluid fills a narrow gap between a moving part and a fixed one, and shearing it produces a torque proportional to viscosity and speed, and inversely proportional to the gap. Friction, by contrast, is a constant torque: a friction hinge tight enough to hold the lid at 30° holds it at any angle, and a looser one lets it fall faster and faster. A damper always lets the lid come down and always slows it. At zero speed it gives no torque: a damper never holds the lid up.

On a lid, inertia is small compared with damping. The lid almost immediately reaches the speed at which the damper torque matches the weight torque, and comes down at that speed:

ω = m·g·d·cos α / c

where m is the lid mass, d the distance from the axis to its center of mass and α the angle measured from the closed (horizontal) position, as in Detent hinge. It is a quasi-static estimate, and it tells you the lid comes down fastest near closing, where cos α = 1, and slowest at the top; it reaches the frame at ω = m·g·d / c.

Integrating that speed gives the closing time from a starting angle α₀:

t = (c / (m·g·d)) · ln(sec α₀ + tan α₀)

The logarithm is 1.32 from 60° and 2.44 from 80°. From 90° the time is infinite: with the lid vertical, its weight gives no torque and nothing moves it. A lid that stays open past vertical needs a push to start closing, as Enclosure lids and Knuckle hinges explain.

Real dampers are not linear. Catalogs give the torque at a specific speed and temperature (for example 20 rpm and 23 °C), and below that speed thick oil brakes a little more than proportion would suggest. If you take that point as your reference and the lid always turns more slowly, the calculated time comes out on the short side, which is the safe side. From here on, the article uses the linear model.

The torque from the lid's weight

The weight torque is T_g = m·g·d·cos α. For a uniform lid of depth L, d = L/2. The torque peaks right before closing, at α = 0: T = m·9.81·L/2, the same formula damper catalogs use to pick a model.

Watch the units. Catalogs give torque in gf·cm or kgf·cm: 1 N·m = 10,197 gf·cm, and 1,000 gf·cm = 0.098 N·m. The part number often encodes it: under the most common convention, the first two digits are the mantissa and the last one the power of ten in gf·cm. A "102" is 10 × 10² = 1,000 gf·cm; a "203", 20,000 gf·cm, about 2 N·m.

Neither hinge friction nor lid inertia appears in the formula. The drop test at the end measures their effect.

Off-the-shelf dampers

A gear damper is a coin-sized sealed housing filled with silicone oil, with a rotor on a shaft and a POM pinion (module 0.5 to 1 depending on the model, 20° pressure angle). As of late 2026, most small gear dampers reach 1,000–1,500 gf·cm, about 0.1–0.15 N·m, always measured at a given speed and temperature, typically 20 rpm and 23 °C. Manufacturers' datasheets limit the speed (50 rpm maximum is common) and the working temperature (roughly 0–50 °C). The torque tolerance is wide, ± 20–30 %: distributors' datasheets give figures such as 15 ± 3 N·cm or 2 ± 0.6 N·cm.

Disc and vane dampers, the ones in toilet seats and furniture, sit directly on the hinge axis, on a D or double-D shaft. They are a single part with no gear, but they have to absorb the whole lid torque, so they are rated in whole newton-meters rather than tenths of one. To join that shaft to a printed part, see Fixing a part to a shaft.

One-way or two-way. A one-way damper brakes in one direction only, thanks to an internal freewheel (Sprag and roller one-way clutches): the lid opens freely and closes slowly. A two-way damper brakes both ways and makes opening heavy. One-way dampers come in R and L versions. Under the most common convention, R brakes clockwise rotation seen from the shaft end, but check the manufacturer's drawing. The hinge on the other side takes the opposite hand. Fitting one backwards is the most common mistake.

A damper is not a stop either. Catalogs require separate stops at the open and closed positions, so the damper never carries load at rest. Put them on the lid and the box, as in Enclosure lids.

Linear dampers for drawers and cabinet doors apply the same principle to a straight stroke: they brake the last 10–20 mm. You buy them ready-made and print the housing. They are the ones that sit alongside the closing spring in Concealed cup hinges.

The gear multiplies by i²

If the lid drives the damper pinion through a sector of ratio i (sector teeth over pinion teeth), the effect is twofold: the damper turns i times faster, so its torque grows i times, and that torque reaches the lid multiplied by i again. At the lid, c_lid = c_damper · i². A 4:1 reduction does not quadruple the braking: a 1,000 gf·cm damper behind a 4:1 sector brakes like one 16 times larger mounted directly on the axis. That is why a 0.1 N·m damper is enough for a 0.3 N·m lid.

The first limit is the damper speed: i·ω, at the moment the lid reaches the frame, has to stay below its maximum and, ideally, below its rated speed. The second is the force on the teeth: T / r_sector. In a free fall that load is small, but the same i² works against you when someone shuts the lid by hand. The worked example puts a number on it.

The printed sector takes the same module and pressure angle (20°) as the damper pinion. Take the center distance and backlash from Spur gears, and the tooth strength from Sizing a gear that holds.

Print the sector flat, with the teeth in the XY plane, so the flanks come out round and without steps. Fix the damper housing in a printed pocket with two screws or a bayonet, not glue, so you can replace it. The pocket prints tight for the reasons in Why holes print small; allow for it when you size it.

Worked example: a 300 g lid

A uniform 300 g lid, 200 mm deep: d = 100 mm. The target is the criterion in Bansbach's selection guide: damping is noticeable if the lid, released at 60°, takes 2 s or more to close. The lid opens to 100°, against a stop, and from there it has to be pushed past vertical; the sector has to cover that whole travel.

300 g lid with a gear damper
Step Calculation Result
Lid torque at closing (α = 0) 0.3 × 9.81 × 0.10 0.294 N·m ≈ 3,000 gf·cm
Damper one-way, 1,000 gf·cm at 20 rpm (2.09 rad/s) 0.098 N·m
Its coefficient 0.098 / 2.09 c = 0.047 N·m·s/rad
i = 1 0.047 / 0.294 × 1.32 0.21 s: no good
i = 2 c_lid = 0.19 0.84 s
i = 3 c_lid = 0.42 1.9 s: borderline
i = 4 c_lid = 0.047 × 16 = 0.75 3.4 s ✓
Speed on reaching the frame 0.294 / 0.75 0.39 rad/s ≈ 22°/s
Damper speed 4 × 0.39 1.57 rad/s = 15 rpm, below its 20 rpm ✓
Gearing pinion m = 1, z = 12 (pitch Ø12 mm); sector m = 1, z = 48 (pitch Ø48 mm) center distance 30 mm (the "Spur gear" already has its backlash: do not move the shafts apart)
Teeth used 100° of a 48-tooth sector ≈ 13 teeth
Tooth force, free fall 0.294 / 0.024 ≈ 12 N
Tooth force, shut by hand at 180°/s 0.75 × 3.14 / 0.024 ≈ 100 N; pinion at ≈ 120 rpm
Torque tolerance ± 25 % c_lid = 0.56–0.94 2.5–4.2 s
Force to open at the edge 0.294 / 0.200 ≈ 1.5 N + the freewheel drag

No small gear damper mounted directly on the axis can brake this lid: a 1,500 gf·cm one would give c = 0.070 and 0.3 s. The 4:1 sector is what lets you use the small one. The sector does not have to be a whole gear: an arc of about 17 teeth is enough, the 13 the travel uses plus two spare at each end, so the pinion stays in mesh when it reaches the stops. The 12-tooth pinion belongs to the damper in this example; check yours on its datasheet.

The hand-closing row is the design case. The 12 N of free fall break nothing, but someone pushing the lid shut quickly drives the pinion to more than twice the usual 50 rpm and multiplies the tooth load by eight. If the lid will be shut by hand, size the tooth for T = c_lid·ω_hand with Sizing a gear that holds, or lower i and fit a bigger damper.

αd = L/2LidWeightSectorDamperT_g = m·g·d·cos α0123450153045602 s criterion from 60°i = 2i = 3i = 4± 25 % torqueTime (s)Lid angle α (°)
The weight torque falls as the lid opens, so the lid comes down fastest near closing. Time grows with i²: at i = 4 the 300 g lid takes 3.4 s from 60°, above the 2 s criterion; the band is the ± 25 % torque tolerance.
diagram
Friction, spring or damper, and which damper to choose, in five questions.

Printing an oil damper

A cylindrical rotor of radius r and length L turns inside a housing full of silicone oil, separated from it by a uniform gap h; an O-ring seals the shaft. Assuming Couette flow and a Newtonian fluid, and adding the cylindrical wall and the rotor's two flat faces with the same gap:

T = (2π·η·r³·L / h + π·η·r⁴ / h) · ω

Torque is inversely proportional to h: the gap is the tuning parameter.

Silicone oil is sold by viscosity grade, from 1,000 to 1,000,000 cSt, from hobby shops (differential and shock oils for RC cars) and lab suppliers. To convert to Pa·s: η ≈ cSt × 0.97 × 10⁻³. It only behaves as Newtonian below a critical shear rate, and the thicker the oil, the lower that rate.

Silicone oil: where the calculation holds (Gelest, conventional silicone fluids)
Viscosity Critical shear (Newtonian below) Apparent viscosity at 10,000 s⁻¹
1,000 cSt 2,500 s⁻¹ 850 cSt
12,500 cSt 200 s⁻¹ 4,700 cSt
30,000 cSt 150 s⁻¹ 6,000 cSt
100,000 cSt 30 s⁻¹ 8,200 cSt

Work out the shear rate, γ̇ = r·ω / h, and pick a grade whose critical shear sits above it. Silicone does not attack PLA, PETG, ABS, ASA, PC or PA (Friction and wear), but it contaminates any surface you later want to glue or paint.

An example. With r = 15 mm, L = 15 mm, h = 0.3 mm and 30,000 cSt oil (η ≈ 29 Pa·s), c ≈ 0.031 from the wall + 0.015 from the faces = 0.046 N·m·s/rad: practically the same as the bought 1,000 gf·cm damper. Behind the same 4:1 sector, the 300 g lid closes in 3.3 s from 60°. The shear at 15 rpm is 0.015 × 1.57 / 0.0003 ≈ 80 s⁻¹, below 150: the calculation holds. With 100,000 cSt in the same gap, the oil would already be shear-thinning. The gap holds about 0.85 ml of oil.

Your printer sets the torque. With h = 0.3 ± 0.1 mm, c ranges from −25 % to +50 %: at h = 0.2 mm, c = 0.069 and 5.0 s; at h = 0.4 mm, c = 0.035 and 2.5 s. Print the rotor and housing with the axis vertical so both come out round. A 0.3 mm gap per side is a free-running fit (Real printed clearances). An off-center gap brakes harder and unevenly. Print a first batch, time it and correct with the oil grade: that costs less than reprinting.

Seal it. A printed wall weeps oil between layers: the housing has to be watertight (Watertight printed parts), and the shaft takes an O-ring (O-ring grooves). For a slow rotation of less than one turn, like this one, the dynamic squeeze of 10–16 % is fine; do not stretch the O-ring over the shaft, because a stretched O-ring on a rotating shaft heats up and shrinks. The seal-free alternative is damping grease, the kind used in focusers and in the knobs of optical and audio equipment: it does not flow, so a lip to contain it is enough. Manufacturers publish nothing you could calculate its torque from: measure it.

Fill it without air. Pour the oil into the housing, push the rotor in slowly and turn it until no more bubbles rise. With air in the gap, the lid drops a few degrees and then brakes.

Air damper from a syringe

An air damper is a piston that pushes air out through a small orifice. In a printed cylinder, air leaks around the piston; so buy a plastic syringe, with its smooth bore and its own rubber seal. Print the mounts, the lever off the lid and a cap with the orifice. On closing, the lid pushes the plunger; on opening, the syringe has to refill quickly through a check valve: a TPU flap or a ball (Check valves and taps).

Take a Ø20 mm syringe (314 mm²) and a 50 mm lever on the 300 g lid. Near closing you need F = 0.294 / 0.05 ≈ 5.9 N, that is Δp ≈ 19 kPa; at 0.39 rad/s on a 50 mm arm, the flow is about 6 ml/s. The orifice equation (Cd ≈ 0.6, air at 1.2 kg/m³) gives an orifice of about Ø0.27 mm: 0.3 at most. A Ø0.4 one has more than twice the area and barely brakes. A hole like that cannot be printed accurately: use an M3 set screw as a needle valve throttling a cross-drilled hole, a blunt dispensing needle, or a tiny hole you open up by trial.

There are two differences from oil. Through an orifice, force grows with the square of speed: it brakes a fast fall hard and a slow one hardly at all. And air behaves like a spring: at 19 kPa the trapped air compresses by about 16 %, so the lid gives a little before braking and can bounce if the trapped volume is large. Keep the dead volume small.

It suits a straight stroke, costs little and barely notices temperature. Skip it if you need a precise time or a long life somewhere dusty.

Cold and heat

Oil viscosity drops as it warms up. Silicone oil is the most stable: its viscosity–temperature coefficient is 0.61 (at 99 °C it keeps 39 % of its viscosity at 38 °C). Extrapolated to indoor temperatures, that works out at about 2 % per °C, a little more the colder it gets. A damper that closes in 3 s at 20 °C takes about 4 s at 5 °C and about 2.2 s at 35 °C. Mineral oils change far more: do not use them in a printed damper, and they can also attack PC and ABS (Friction and wear).

Catalogs give the torque at 23 °C, and a gear damper usually works between 0 and 50 °C. A lid in a car or a garage sees both extremes. Size for the hot case, the one with the shortest time, and check with that 2 % per °C that in the cold the close stays within the time you accept.

The housing matters too: under load, PLA's limit is around 40 °C (Heat, cold, sunlight and chemicals). Inside a car, never PLA or PETG: an unloaded housing goes in ASA or PC, and one that carries a load in the sun, in a fiber-filled compound.

When it fails

What usually goes wrong with a damped lid
Symptom Cause Fix
The lid bangs at the end The damper stops acting at the end (short sector or skipping pinion) or i too low Longer sector, higher i
Opening is heavy Two-way damper, or one-way fitted the wrong way round (R/L) Swap it or turn it over
Drops a few degrees, then brakes Air in the oil, backlash in the gear or the freewheel Refill without bubbles; check the centers are at the theoretical distance and the freewheel play
Stops halfway Starts near vertical, or hinge friction beats T_g up there Release it lower or reduce hinge friction
Fast in summer, slow in winter Viscosity falls with temperature Silicone oil, size for the hot case
Closes faster every week Oil leaking through a printed wall or the shaft Watertight walls, O-ring, or grease
Two printed dampers close differently Spread in h (torque ∝ 1/h) Measure each one, change the oil grade
The pinion skips or the sector wears Wrong center distance or mismatched modules Use the bought pinion's module and work out the centers from the pitch radii
Broken tooth or leaking damper after shutting by hand i² multiplies the force of a fast close Tooth sized for c_lid·ω_hand, or lower i and a bigger damper
The housing cracks or leaks at the stop The damper is acting as the stop Separate stop on the lid and the box
The syringe bounces Too much dead volume, orifice too tight Shorter barrel, open up the needle valve

How to test it

Drop test. Lift the lid to 60°, let go, film it on your phone at 60 frames per second or more and count the frames until it touches the frame. The catalog criterion is 2 s or more from 60°; your target depends on the product. Repeat five times: scatter between runs gives away air or backlash.

Temperature. Repeat after an hour in the fridge (≈ 5 °C) and somewhere warm (≈ 35 °C), and compare the difference with the predicted 2 % per °C.

Life. Run 1,000 open-close cycles on the rig from Testing a mechanism before you trust it, time it again and weigh the printed damper on 0.01 g jewelry scales to catch leaks.